Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 362
Filtrar
1.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629420

RESUMO

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Curr Cardiol Rep ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619711

RESUMO

PURPOSE OF REVIEW: Acute coronary syndromes (ACS) are a major global health concern. Percutaneous coronary intervention (PCI) with new-generation drug-eluting stents (DES) has been endorsed as safe and effective in the management of culprit and non-culprit lesions of ACS. However, permanent metallic implants may have drawbacks, including the need for prolonged dual antiplatelet therapy (DAPT) and the risk of long-term stent-related complications. An alternative approach using drug-coated balloons (DCBs) is gaining growing interest, having the potential of delivering therapy directly to vulnerable plaques, avoiding the need for permanent metallic implants, and potentially allowing for better long-term medical treatment. Despite limited evidence, DCB is being explored in several patients' subgroups. This review aims to discuss the existing evidence regarding DCB in ACS management. RECENT FINDINGS: DCB appears to be a promising strategy in the management of ACS, showing comparable angiographic and clinical results as compared to new-generation DES in relatively small clinical trials or large prospective registries. The advantage of avoiding permanent implants is particularly appealing in this setting, where DCB has the potential of delivering anti-atherogenic local therapy directly to vulnerable plaques still amenable to atherogenic regression. This review seeks to underline the theoretical background of DCB use and reports the available evidence in its support in the specific setting of ACS. In the context of ACS, the use of DCB is highly attractive, offering a dedicated anti-atherogenic local therapy, capable of addressing a broad range of vulnerable plaques and patients.

3.
Am J Cardiol ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636623

RESUMO

Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a non-uniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy and outcomes of infolding during Medtronic™ Evolut TAVI. Between January 2018 and March 2022 all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into two groups; peri-procedural characteristics and 30-day outcomes were compared. A total of 1470 patients were included. Twenty-three infolding cases (1.6%) were detected. Pre-procedural imaging showed larger aortic anatomy and higher calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%; p<0.001). Short-term follow-up showed higher all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%; p<0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%; p=0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of high native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or post-dilation.

4.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479968

RESUMO

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia
5.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
6.
Am J Cardiol ; 217: 144-152, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38431052

RESUMO

Coronary angiography (CA) is poorly correlated with non-invasive myocardial stress imaging (NSI) and myocardial ischemia is often observed in patients with unobstructed coronary arteries. Moreover, the diagnostic performance of combined epicardial and microcirculatory angiography-derived physiological assessment and its correlation with NSI remains unknown. A total of 917 coronary vessels in 319 patients who underwent both CA and NSI were included in this multicenter observational retrospective analysis. Quantitative flow ratio (QFR) and angiography-derived index of microcirculatory resistance (IMRangio) analyses were performed to estimate coronary epicardial and microcirculatory function respectively. NSI demonstrated evidence of myocardial ischemia in 76% of the cases. IMRangio (36 [22 to 50] vs 29 [21 to 41], p <0.001) was significantly higher and QFR (0.92 [0.78 to 0.99] vs 0.97 [0.91 to 0.99], p <0.001) was significantly lower in vessels subtending ischemic territories. Overall, the diagnostic accuracy of QFR was moderate (area under the curve of receiver operating characteristic [AUCROC] 0.632 [95% confidence interval [CI] 0.589 to 0.674], p <0.0001) but it was higher in patients with normal microcirculatory function (AUCROC = 0.726 [95% CI 0.669 to 0.784], p <0.0001, p Value for AUCROC comparison = 0.009). Combined QFR/IMRangio assessment provided incremental diagnostic performance compared with the evaluation of epicardial or microcirculatory districts in isolation (p Value for AUC comparison <0.0001) and it was able to identify the predominant mechanism of myocardial ischemia in 77% of the patients with positive NSI. Our study suggests the value of a combined angiography-derived assessment of epicardial and microvascular function for the definition of the predominant mechanism of myocardial ischemia in patients with suspected coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico , Estudos Retrospectivos , Microcirculação , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Isquemia Miocárdica/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
7.
JACC Case Rep ; 29(9): 102287, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38500538

RESUMO

The long-established utility of multiwindow interrogation in echocardiography (suprasternal notch, right and left sternal border, apex, and subxiphoid) is sometimes not systematically implemented in routine practice. This case series emphasizes the pivotal importance of such practice for the systematic assessment of aortic valve stenosis and in the evaluation of left ventricular outflow tract and the aorta.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38535984

RESUMO

Renal denervation (RDN) is a safe and effective strategy for the treatment of difficult to treat hypertension. The blood pressure (BP)-lowering efficacy of RDN is comparable to those of many single antihypertensive medications and it allows to consider the RDN as a valuable option for the treatment of difficult to treat hypertension together with lifestyle modifications and medical therapy. A multidisciplinary team is of pivotal importance from the selection of the patient candidate for the procedure to the post-procedural management. Further studies are needed to investigate the effect of RDN on clinical outcomes and to better identify the predictors of BP response to RDN in order to recognize the patients who are more likely to benefit from the procedure.

10.
Circ Cardiovasc Interv ; 17(3): e013556, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38375667

RESUMO

BACKGROUND: Patients with ST-segment-elevation myocardial infarction but no coronary microvascular injury are at low risk of early cardiovascular complications (ECC). We aim to assess whether nonhyperemic angiography-derived index of microcirculatory resistance (NH-IMRangio) could be a user-friendly tool to identify patients at low risk of ECC, potentially candidates for expedited care pathway and early hospital discharge. METHODS: Retrospective analysis of 2 independent, international, prospective, observational cohorts included 568 patients with ST-segment-elevation myocardial infarction. NH-IMRangio was calculated based on standard coronary angiographic views with 3-dimensional-modeling and computational analysis of the coronary flow. RESULTS: Overall, ECC (a composite of cardiovascular death, cardiogenic shock, acute heart failure, life-threatening arrhythmias, resuscitated cardiac arrest, left ventricular thrombus, post-ST-segment-elevation myocardial infarction mechanical complications, and rehospitalization for acute heart failure or acute myocardial infarction at 30 days follow-up), occurred in 54 (9.3%) patients. NH-IMRangio was significantly correlated with pressure/thermodilution-based index of microcirculatory resistance (r=0.607; P<0.0001) and demonstrated good accuracy in predicting ECC (area under the curve, 0.766 [95% CI, 0.706-0.827]; P<0.0001). Importantly, ECC occurred more frequently in patients with NH-IMRangio ≥40 units (18.1% versus 1.4%; P<0.0001). At multivariable analysis, NH-IMRangio provided incremental prognostic value to conventional clinical, angiographic, and echocardiographic features (adjusted-odds ratio, 14.861 [95% CI, 5.177-42.661]; P<0.0001). NH-IMRangio<40 units showed an excellent negative predictive value (98.6%) in ruling out ECC. Discharging patients with NH-IMRangio<40 units at 48 hours after admission would reduce the total in-hospital stay by 943 days (median 2 [1-4] days per patient). CONCLUSIONS: NH-IMRangio is a valuable risk-stratification tool in patients with ST-segment-elevation myocardial infarction. NH-IMRangio guided strategies to early discharge may contribute to safely shorten hospital stay, optimizing resources utilization.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Microcirculação , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Infarto do Miocárdio/etiologia , Alta do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Resultado do Tratamento , Estudos Observacionais como Assunto
11.
Am J Cardiol ; 219: 60-70, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).

12.
Artigo em Inglês | MEDLINE | ID: mdl-38319610

RESUMO

AIMS: We sought to investigate the association with outcome of left atrial strain in a large cohort of patients with at least moderate aortic stenosis (AS). METHODS AND RESULTS: we analyzed 467 patients (mean age 80.6 ± 8.2 years; 51% men) with at least moderate AS, and sinus rhythm. The primary study endpoint was the composite of all-cause mortality and hospitalizations for heart failure. After a median follow-up of 19.2 (IQR 12.5-24.4) months, 96 events occurred. Using the ROC curve analysis, the cut-off value of peak atrial longitudinal strain (PALS) more strongly associated with outcome was < 16% [AUC 0.70 (95% CI: 0.63-0.78), p<0.001]. The Kaplan Meier curves demonstrated a higher rate of events for patients with PALS<16% (log-rank p<0.001). On multivariable analysis, PALS [aHR 0.95 (95% CI 0.91 - 0.99), p=0.017] and age were the only variables independently associated with the combined endpoint. PALS provided incremental prognostic value over left ventricular (LV) global longitudinal strain, LV ejection fraction, and right ventricular function. Subgroup analysis revealed that impaired PALS was independently associated with outcome also in the subgroups of paucisymptomatic patients [aHR 0.98 (95% CI 0.97 - 0.98), p=0.048], moderate AS [aHR 0.92, (95% CI 0.86 - 0.98), p=0.016], and low-flow AS [aHR 0.90, (95% CI 0.83 - 0.98), p=0.020]. CONCLUSION: In our patients with at least moderate AS, PALS was independently associated with outcome. In asymptomatic patients, PALS could be a potential marker of subclinical damage, leading to better risk stratification, and, potentially, to earlier treatment.

13.
Eur J Heart Fail ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38404225

RESUMO

AIMS: Dilated cardiomyopathy (DCM) with arrhythmic phenotype combines phenotypical aspects of DCM and predisposition to ventricular arrhythmias, typical of arrhythmogenic cardiomyopathy. The definition of DCM with arrhythmic phenotype is not universally accepted, leading to uncertainty in the identification of high-risk patients. This study aimed to assess the prognostic impact of arrhythmic phenotype in risk stratification and the correlation of arrhythmic markers with high-risk arrhythmogenic gene variants in DCM patients. METHODS AND RESULTS: In this multicentre study, DCM patients with available genetic testing were analysed. The following arrhythmic markers, present at baseline or within 1 year of enrolment, were tested: unexplained syncope, rapid non-sustained ventricular tachycardia (NSVT), ≥1000 premature ventricular contractions/24 h or ≥50 ventricular couplets/24 h. LMNA, FLNC, RBM20, and desmosomal pathogenic or likely pathogenic gene variants were considered high-risk arrhythmogenic genes. The study endpoint was a composite of sudden cardiac death and major ventricular arrhythmias (SCD/MVA). We studied 742 DCM patients (45 ± 14 years, 34% female, 410 [55%] with left ventricular ejection fraction [LVEF] <35%). During a median follow-up of 6 years (interquartile range 1.6-12.1), unexplained syncope and NSVT were the only arrhythmic markers associated with SCD/MVA, and the combination of the two markers carried a significant additive risk of SCD/MVA, incremental to LVEF and New York Heart Association class. The probability of identifying an arrhythmogenic genotype rose from 8% to 30% if both early syncope and NSVT were present. CONCLUSION: In DCM patients, the combination of early detected NSVT and unexplained syncope increases the risk of life-threatening arrhythmic outcomes and can aid the identification of carriers of malignant arrhythmogenic genotypes.

15.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38180419

RESUMO

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de Risco
16.
Clin Res Cardiol ; 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38170246

RESUMO

BACKGROUND: Cardiac allograft vasculopathy (CAV) is still the main drawback of heart transplantation (HTx) and percutaneous coronary intervention (PCI) is a palliative measure because of the high incidence of failure. OBJECTIVE: This study aimed to investigate the safety and efficacy of bioresorbable scaffolds (BRSs) as potential novel therapeutic tool for the treatment of coronary stenoses in CAV. METHODS: This is a multicenter, single-arm, prospective, open-label study (CART, NCT02377648), that included patients affected by advanced CAV treated with PCI and second-generation ABSORB BRS (Abbott Vascular). The primary endpoint was the incidence of 12-month angiographic in-segment scaffold restenosis (ISSR). Secondary endpoints were the incidence of major adverse cardiac events (MACEs) at 12- and 36-month follow-up and the incidence of ISSR at 36 months. A paired intracoronary imaging analysis at baseline and follow-up was also performed. RESULTS: Between 2015 and 2017 35 HTx patients were enrolled and treated for 44 coronary lesions with 51 BRSs. The primary endpoint occurred in 13.5% of the lesions (5/37), with a cumulative ISSR rate up to 3 years of 16.2% (6/37). Angiographic lumen loss was 0.40 ± 0.62 mm at 12 months and 0.53 ± 0.57 mm at 36 months. Overall survival rate was 91.4% and 74.3%, and MACEs incidence 14.2% and 31.4% at 12 and 36 months, respectively. At the paired intracoronary imaging analysis, a significant increase of the vessel external elastic membrane area in the treated segment and some progression of CAV proximally to the BRS were detected. CONCLUSIONS: BRS-based PCI for the treatment of CAV is feasible and safe, with an ISSR incidence similar to what reported in retrospective studies with drug-eluting stents.

17.
Eur Heart J ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38190428

RESUMO

BACKGROUND AND AIMS: Severe aortic stenosis (AS) is the guideline-based indication for aortic valve replacement (AVR), which has markedly increased with transcatheter approaches, suggesting possible increasing AS incidence. However, reported secular trends of AS incidence remain contradictory and lack quantitative Doppler echocardiographic ascertainment. METHODS: All adults residents in Olmsted County (MN, USA) diagnosed over 20 years (1997-2016) with incident severe AS (first diagnosis) based on quantitatively defined measures (aortic valve area ≤ 1 cm2, aortic valve area index ≤ 0.6 cm2/m2, mean gradient ≥ 40 mmHg, peak velocity ≥ 4 m/s, Doppler velocity index ≤ 0.25) were counted to define trends in incidence, presentation, treatment, and outcome. RESULTS: Incident severe AS was diagnosed in 1069 community residents. The incidence rate was 52.5 [49.4-55.8] per 100 000 patient-year, slightly higher in males vs. females and was almost unchanged after age and sex adjustment for the US population 53.8 [50.6-57.0] per 100 000 residents/year. Over 20 years, severe AS incidence remained stable (P = .2) but absolute burden of incident cases markedly increased (P = .0004) due to population growth. Incidence trend differed by sex, stable in men (incidence rate ratio 0.99, P = .7) but declining in women (incidence rate ratio 0.93, P = .02). Over the study, AS clinical characteristics remained remarkably stable and AVR performance grew and was more prompt (from 1.3 [0.1-3.3] years in 1997-2000 to 0.5 [0.2-2.1] years in 2013-16, P = .001) but undertreatment remained prominent (>40%). Early AVR was associated with survival benefit (adjusted hazard ratio 0.55 [0.42-0.71], P < .0001). Despite these improvements, overall mortality (3-month 8% and 3-year 36%), was swift, considerable and unabated (all P ≥ .4) throughout the study. CONCLUSIONS: Over 20 years, the population incidence of severe AS remained stable with increased absolute case burden related to population growth. Despite stable severe AS presentation, AVR performance grew notably, but while declining, undertreatment remained substantial and disease lethality did not yet decline. These population-based findings have important implications for improving AS management pathways.

18.
Eur Heart J Qual Care Clin Outcomes ; 10(1): 25-35, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-37286294

RESUMO

AIMS: As a consequence of untimely or missed revascularization of ST-elevation myocardial infarction (STEMI) patients during the COVID-19 pandemic, many patients died at home or survived with serious sequelae, resulting in potential long-term worse prognosis and related health-economic implications.This analysis sought to predict long-term health outcomes [survival and quality-adjusted life-years (QALYs)] and cost of reduced treatment of STEMIs occurring during the first COVID-19 lockdown. METHODS AND RESULTS: Using a Markov decision-analytic model, we incorporated probability of hospitalization, timeliness of PCI, and projected long-term survival and cost (including societal costs) of mortality and morbidity, for STEMI occurring during the first UK and Spanish lockdowns, comparing them with expected pre-lockdown outcomes for an equivalent patient group.STEMI patients during the first UK lockdown were predicted to lose an average of 1.55 life-years and 1.17 QALYs compared with patients presenting with a STEMI pre-pandemic. Based on an annual STEMI incidence of 49 332 cases, the total additional lifetime costs calculated at the population level were £36.6 million (€41.3 million), mainly driven by costs of work absenteeism. Similarly in Spain, STEMI patients during the lockdown were expected to survive 2.03 years less than pre-pandemic patients, with a corresponding reduction in projected QALYs (-1.63). At the population level, reduced PCI access would lead to additional costs of €88.6 million. CONCLUSION: The effect of a 1-month lockdown on STEMI treatment led to a reduction in survival and QALYs compared to the pre-pandemic era. Moreover, in working-age patients, untimely revascularization led to adverse prognosis, affecting societal productivity and therefore considerably increasing societal costs.


Assuntos
COVID-19 , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , COVID-19/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Pandemias , Estresse Financeiro , Controle de Doenças Transmissíveis
19.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982161

RESUMO

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Desenho de Prótese
20.
EuroIntervention ; 20(5): e289-e300, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-37982178

RESUMO

BACKGROUND: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances. AIMS: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI. Coronary microvascular dysfunction (CMD) was defined as the lowest MRR tertile of the study cohort. Haemodynamic measurements were performed at baseline and then repeated immediately after TAVI. EVCD and markers of a low-flow phenotype were assessed with echocardiography. RESULTS: A total of 134 patients were included in this study. Patients with low MRR were more frequently females, had a lower estimated glomerular filtration rate and a higher rate of atrial fibrillation. MRR was significantly lower in patients with advanced EVCD (median 1.80 [1.26-3.30] vs 2.50 [1.87-3.41]; p=0.038) and in low-flow, low-gradient AS (LF LG-AS) (median 1.85 [1.20-3.04] vs 2.50 [1.87-3.40]; p=0.008). Overall, coronary microvascular function tended to improve after TAVI and, in particular, MRR increased significantly after TAVI in the subgroup with low MRR at baseline. However, MRR was significantly impaired in 38 (28.4%) patients immediately after TAVI. Advanced EVCD (adjusted odds ratio 3.08 [1.22-7.76]; p=0.017) and a low-flow phenotype (adjusted odds ratio 3.36 [1.08-10.47]; p=0.036) were significant predictors of CMD. CONCLUSIONS: In this observational, hypothesis-generating study, CMD was associated with extravalvular cardiac damage and a low-flow phenotype in patients with severe AS undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Isquemia Miocárdica , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...